DSCC Screening Sequence for SMD Listed Devices (Discrete)

Semelab Hi-Rel Screening Options (585,924 bytes)
(includes all screening and inspection flows)

Cage Number U3158


Method 5005: Table I Group A electrical tests for class level B
Examination or Test Quality/Accept Observations
Subgroup 1
Static Tests
116/0 Tamb = 25°C
Subgroup 2
Static Tests
116/0 Tamb = Tmax
Subgroup 3
Static Tests
116/0 Tamb = Tmin
Subgroup 4
Dynamic Tests
116/0 Tamb = 25°C
Subgroup 5
Dynamic Tests
116/0 Tamb = Tmax
Subgroup 6
Dynamic Tests
116/0 Tamb = Tmin
Subgroup 7
Functional Tests
116/0 Tamb = 25°C
Subgroup 8a
Functional Tests
116/0 Tamb = Tmax
Subgroup 8b
Functional Tests
116/0 Tamb = Tmin
Subgroup 9
Switching tests
116/0 Tamb = 25°C
Subgroup 10
Switching tests
116/0 Tamb = Tmax
Subgroup 11
Switching tests
116/0 Tamb = Tmin



Method 5005: Table IIb: Group B tests for class level B
Test note MIL-STD
-883
method
Condition Quantity/accept
or sample
size/accept
Subgroup

Resistant to solvents
(3) 2015   3/0
Subgroup 2

Solderability

(4)

2003

soldering temp
245°C ± 5°C

sample size
number = 22, c = 0

Subgroup 3

Bond strength
1) Thermo-compression
2) Ultrasonic / Wedge
3) Flip-chip
4) Beam lead

(5)

2011




1) Test Condition C or D
2) Test Condition C or D
3) Test Condition F
4) Test Condition H

sample size
number = 15, c = 0


3) Resistance to solvents testing required only on devices using inks or paints as the marking or contrast.
4) Devices submitted for solderability shall be in the same lead finish as shipped product and must have been through the temp/time exposure of burn in except for devices which have been hot solder dipped or have tin-lead fusing after burn-in.
5) Unless otherwise specified the sample size number for condition C or D is the number of bond pulls selected from a minimum number of 4 devices and for condition F or H is the number of dice (not bonds)

Method 5005: Table III: Group C (Die related tests) for class level B
Test MIL-STD-883
method
Condition Quantity/accept or
sample size/accept
Subgroup 1

a) Steady-state life test

1005

Test condition to be specified
(1000 hours at 125°C
or equivalent in accordance
with table 1)

sample size
number = 45, c = 0

b) End-point electrical parameters   As specified in the applicable
device specification
 

Method 5005: Table IV Group D (package related tests) for class level B
Test MIL-STD-883
method
Condition Quantity/accept or
sample size/accept
Subgroup 1 (2)      

Physical Dimensions

2016

  sample size
number = 15, c = 0
Subgroup 2      

a) Lead Integrity (3)
b) Seal - Fine & Gross leak (4)

2004
1014

Test Condition B (lead fatigue)
As applicable

  sample size
number = 45, c = 0

Subgroup 3 (5)

     
a) Thermal Shock

b) Temp Cycle

c) Moisture resistance
 
1011

1010

1004
Test cond B as a min.
15 cycles min
Test Condition C.
100 cycles min
sample size
number = 15, c = 0
d) Visual Examination   In accordance with visual criteria method 1004 and 1010
e) Seal - Fine & Gross leak
f) End Point Electricals
1010 as applicable
As specified in the applicable
device specification
 
Subgroup 4 (5)      
a) Mechanical Shock
b) Vibration, variable frequency
c) Constant Acceleration
d) Seal - Fine & Gross leak
e) Visual examination
f) End point Electricals
2002
2007
2001
1014
Test condition B minimum
Test condition A minimum
Test condition E minimum
(Y1 only)

In accordance with method
1010 or 1101
As specified in applicable
device specification
sample size
number = 15, c = 0
Subgroup 5 (2)    
a) Salt Atmosphere
b) Visual Examination
c) Seal - Fine & Gross leak
1009
1014
Test condition A minimum
In accordance with
method 1009
sample size
number = 15, c = 0
Subgroup 6 (2)    
a) Internal water-vapour
   content
1018 5000ppm max water content
at 100°C
3/0 or 5/1
Subgroup 7 (2)    
a) Adhesion of Lead
    finish (12)
2025   sample size
number = 15, c = 0
Subgroup 8 (2)    
a) Lid Torque 2024  

5/0

1) In line monitor data may be substituted for subgroups D1,D2,D6,D7 and D8 upon approval by the qualifying activity. The monitors shall be performed by package type and to the specified subgroup test method.
2) Electrical reject devices from the same inspection lot may be used for samples.
3) The sample size number of 45, C=0 for lead integrity shall be based on the number of leads or terminals tested and shall be taken from a minimum of 3 devices.
4) Seal tests need only be performed on packages having leads exiting through a glass seal.
5) Devices used in subgroup 3 can be used in subgroup 4.
8) End point electrical parameters may be performed after moisture resistance and prior to seal test.
12) Sample size based on number of leads.